Essex Groundworks Supplies Ltd Home PageAbout Essex Groundworks Supplies LtdView  a map of our location
 
 
 

Covers & Frames - Iron

Iron Covers & Frames

Ultra Specification BSI Kitemarked BS EN124 E600

150mm Deep - Ultra heavy duty ductile Iron access covers and frames USAGE: Group 4 and 5 - High wheel load. High traffic usage

Features
Manufactured to BS EN124 Class E600
Complies with Design Manual for Roads & Bridges Vol 4 Section 2 Part 5, HA104/02
60 Tonne Safe Test Load
Kitemarked for third party assurance of quality
All products on this page additionally conform to BS 7903 Works safety tested to +10% above EN 124 = 66 Tonnes
And movement technology for improved bonding to bedding material Stiffened frame and extra wide flanges for increased bonding 125mm depth of cover insertion into frames for increased stability 140mm solid bedding width, gives better bonding to mortar Suitable for carriageway, fast moving traffic use and high wheel loads Dimensions increased to allow seatings to be positioned beyond clear opening for extra stability Non rock three point suspension for stability and silent operation Ductile iron for Improved weight to strength ratio Black coated finish

Optional Extras
Locking - Standard Bolts
Locking - Approved High Security Bolts / Keys
Badging - ie FW, SW, Motorway Communications etc
Sealing Plates
Pressure Plates Ventilation Safety Grids
Lifting Keys - key ref : Hkey
Long Handled Lifting Keys - key ref : LHkey

 
Product
Code
Clear
Opening
Frame Depth
Cover Depth of Instertion
Overall
Frame
Frame Area Bearing Preassure
Mass apx Kg
U
KD10E
600x600mm
150mm
125mm
880x880mm
1.5N/mm2
145
U
KD19E
1220x675mm
150mm
125mm
1350x805mm
1N/mm2
225
 

Ultra Specification BSI Kitemarked BS EN124 D400

100mm Deep - Heavy duty ductile Iron access covers and frames USAGE : Group 4 - Carriageways and main roads for fast moving traffic

Features
Manufactured to BS EN124 Class D400 Kitemarked for third party assurance of quality
Ultra products comply with Design Manual for Roads & Bridges Vol 4 Section 2 Part 5, HASO4/02 where a 100mm deep product is appropriate. Ultra products additionally conform to BS 7903 Suitable for carriageway and fast moving traffic 80mm depth of cover Insertion into frames 75mm solid bedding width
40 Tonne safe test load.
Works safety tested to 44 tonnes = +10%
Non rock three point suspension for stability and silent operation Ductile iron for improved weight to strength ratio Black coated finish

Optional Extras
Locking - Standard Bolts
Locking - Approved High Security Bolts / Keys.
Badging - ie FW, SW, Motorway Communications etc
Sealing Plates
Pressure Plates
Safety Grids
Ventilation
Lifting Keys - key ref : Hkey
Long Handled Lifting Keys - key ref : LHkey

 
Product
Code
Clear
Opening
Frame Depth
Cover Depth of Instertion
Overall
Frame
Frame Area Bearing Preassure
Mass apx Kg
 
KD8
450x450mm
100mm
80mm
600x600mm
-
60
 
KD9
600x450mm
100mm
80mm
750x600mm
-
81
U
KD10
600x600mm
100mm
80mm
750x750mm
1.93N/mm2
86
U
KD12
675x675mm
100mm
80mm
825x825mm
1.74N/mm2
104
U
KD14
750x600mm
100mm
80mm
900x750mm
1.79N/mm2
120
U
KD15
750x750mm
100mm
80mm
900x900mm
1.61N/mm2
140
U
KD16
900x600mm
100mm
80mm
1050x750mm
1.62N/mm2
156
U
KD17
900x900mm
100mm
80mm
1050x1050mm
1.5N/mm2
220
U
KD19
1220x675mm
100mm
80mm
1370x825mm
1.3N/mm2
210
 

Ultra Specification BSI Kitemarked BS EN124 D400

150mm deep - Heavy duty ductile iron access covers and frames USAGE: Group 4 - Carriageways. High traffic usage

Features
Manufactured to BS EN124 Class D400
Kitemarked for third party assurance of quality
Ultra products comply with Design Manual for Roads & Bridges Vol 4 Section 2 Part 5. HA104/02
Ultra products additionally conform to BS 7903 Suitable for carriageway and fast moving traffic use 80/125mm depth of cover insertion into frames 75mm solid bedding width
40 Tonne safe test load.
Works safety tested to 44 tonnes = +10%
Non rock three point suspension for added stability and silent operation Ductile iron for improved weight to strength ratio Black coated finish

Optional Extras
Locking - Standard Bolts
Lacking - Approved High Security Bolts / Keys.
Badging - ie FW,SW, Motorway Communications etc
Sealing Plates
Pressure Plates Safety Grids Ventilation
Lifting Keys - key ref : Hkey
Long Handled Lifting Keys - key ref : LHkey

 
Product
Code
Clear
Opening
Frame Depth
Cover Depth of Instertion
Overall
Frame
Frame Area Bearing Preassure
Mass apx Kg
U
KD10-6
600x600mm
150mm
80mm
750x750mm
1.93N/mm2
97
U
KD10-6-125
600x600mm
150mm
125mm
750x750mm
1.93N/mm2
106
U
KD12-6
675x675mm
150mm
80mm
825x825mm
1.73N/mm2
119
U
KD12-6-125
675x675mm
150mm
125mm
825x825mm
1.73N/mm2
125
U
KD14-6
750x600mm
150mm
80mm
900x750mm
1.79N/mm2
145
U
KD15-6
750x750mm
150mm
80mm
900x900mm
1.61N/mm2
175
U
KD16-6
900x600mm
150mm
80mm
1050x750mm
1.62N/mm2
190
U
KD17-6
900x900mm
150mm
80mm
1050x1050mm
1.34N/mm2
265
 

Ultra Specification BSI Kitemarked BS EN124 D400

150mm deep - Heavy duty ductile iron access covers and frames USAGE : Group 4 - Carriageways. High traffic usage

Features

Manufactured to BS EN124 Class D400 Kitemarked for third party assurance of quality
Ultra products comply with Design Manual for Roads & Bridges, Vol 4. Section 2. Part 5. HA104/02 Ultra products additionally conform to BS 7903 Works safety tested to 44 tonnes = +10% Suitable for carriageway and fast moving traffic use Minimum 80mm depth of cover insertion Into frames Minimum 75mm solid bedding width
Non rock three point suspension for stability and silent operation Ductile Iron for Improved weight to strength ratio Black coated finish

Optional Extras
Locking - Standard Bolts
Locking - Approved High Security Bolts / Keys. Badging - ie. FW, SW, Motor Communications etc Sealing Plates
Pressure Plates Safety Grids Ventilation
Lifting Keys - key ref : Hkey
Long Handled Lifting Keys - key ref : LHkey


 
Product
Code
Clear
Opening
Frame Depth
Cover Depth of Instertion
Overall
Frame
Frame Area Bearing Preassure
Mass apx Kg
U
KD19-6
1220x675mm
150mm
80mm
1370x825mm
1.3N/mm2
232
U
KD19-6-125
1220x675mm
150mm
125mm
1370x825mm
1.3N/mm2
232
U
KD20-6
1830x675mm
150mm
80mm
1980x825mm
1.1N/mm2
348
 

BSI Kitemarked BS EN124 C250

75mm deep - Heavy duty ductile Iron single seal solid top access covers and frames USAGE : Group 3 slow moving heavy traffic

Features
Manufactured to BS EN124 Class C250
Kitemarked for third party assurance of quality
Full single seal gives airtight seal when packed with grease Suitable for slow moving heavy traffic Ductile iron for improved weight to strength ratio Black coated finish

Optional Extras
Locking - Standard Bolts
Locking - Approved High Security Bolts / Keys
Badging - ie FW, SW, CAN etc
Sealing Plates Pressure Plates Safety Grids Ventilation
Lifting Keys - Key ref : Hkey
Long Handled Lifting Keys - Key ref : LHkey


 
Product
Code
Clear
Opening
Frame Depth
Overall
Frame
Mass apx Kg
KD60C
450x450mm
75mm
550x550mm
49
KD61C
600x450mm
75mm
700x550mm
60
KD62C
600x600mm
75mm
700x700mm
75
KD63C
750x600mm
75mm
850x700mm
89
KD64C
750x750mm
75mm
850x850mm
119
KD65C
900x600mm
75mm
1000x750mm
121
KD66C
900x900mm
75mm
1000x1000mm
160
 

BSI Kitemarked BS EN124 B125

Medium duty ductile iron access covers and frames
USAGE : Group 2 For use in car parks, pedestrian areas and driveways

Features
Manufactured to BS EN124 class B125 Kitemarked for third party assurance of quality
Single seal versions give airtight seal when packed with grease Slide out units are un-sealed and allow easy removal Suitable for car parks, footways and driveways Ductile iron for improved weight to strength ratio Black coated finish

Optional Extras
Locking - Standard screws
Locking - Approved High Security Bolts / Keys Badglng - ie FW, SW, CAN etc Sealing Plates
Safety Grids Ventilation
Lifting Keys-Key ref :LKey


 
Product
Code
Clear
Opening
Type
Frame Depth
Overall
Frame
Mass apx Kg
#KD31
450mm Ø
Single Seal
25mm
550mm Ø
19
_KD31L
450mm Ø
Single Seal
25mm
550mm Ø
19
KD3240
450x450mm
Single Seal
40mm
540x540mm
30
KD3340
600x450mm
Single Seal
40mm
690x540mm
38
KD3340S
600x450mm
Slide Out
40mm
690x540mm
34
KD3375W
600x450mm
Plain
75mm
760x610mm
41
KD3440
600x600mm
Single Seal
40mm
690x690mm
47
KD3340S
600x600mm
Slide Out
40mm
690x690mm
40
KD3475
600x600mm
Plain
75mm
690x690mm
50
KD34C
600mm Ø
Single Seal
40mm
690mm Ø
36
KD34AS
675x675mm
Slide Out
40mm
765x765mm
50
KD3540
750x600mm
Single Seal
40mm
840x690mm
60
KD3640S
750x750mm
Slide Out
40mm
850x850mm
72
KD3740
900x600mm
Single Seal
40mm
1000x700mm
66
KD3840S
1220x675mm
twin cover
Slide Out
40mm
1320x775mm
110
# KD31 has a frame spigot to suit PPI Chambers
_ KD31L as KD31 but Locked
 

BS EN124 A15

Light duty grey iron single/double seal access covers and frames Usage : Areas accessible only by pedestrians and pedal cyclists

Features
Manufactured to BS EN124 Class A15
Single seal versions gives airtight seal when packed with grease Double sealed versions available for additional sealing
Suitable for areas only accessible by pedestrians and pedal cyclists. 1.5 Tonne safe test load
Black coated finish

Optional Extras
Locking - Standard Screws
Locking - Approved High Security Screws / Keys Badging - i.e. FW, SW. CATV etc.

Product
Code
Clear
Opening
Ceiling Detail
Cover Type
E10A1
450x450mm
Single
Solid top
E10B1
600x450mm
Single
Solid top
E10C
600mm Ø
Single
Solid top
E10C1
600x600mm
Single
Solid top
E10D
750x600mm
Single
Solid top
E10F
900x600mm
Single
Solid top
E11B
600x450mm
Double
Solid top
E11C
600x600mm
Double
Solid top
E15B
600x450mm
Single
Recessed
E15C
600x600mm
Single
Recessed
E16B
600x450mm
Double
Recessed
E16C
600x600mm
Double
Recessed

Circular covers and frames for PPI Chambers
Product
Code
Clear
Opening
Sealing Detail
Cover Type
Unit Description
E10AC
450mm Ø
Single
Solid top
Cast cover & frame
E10APL
450mm Ø
Single
Solid top
Locking polypropylene cover & frame
E10ACP
450mm Ø
Single
Solid top
Cast cover & plastic frame
E10ACPL
450mm Ø
Double
Solid top
Locking cast cover & plastic frame
E10ADS
450mm Ø
Double
Solid top
Locking cast cover & frame